+971 4 320 3957 sales@misbahswitchgear.com Dubai, United Arab Emirates
Switchgear Manufacturer & Electrical Supplier
Multispan Catalogue

Multispan Model Index — Full Price & Datasheet Catalogue

Every Multispan model we distribute in the UAE & GCC, with ordering codes and part-number variants. Click any model for specifications, datasheet and a price/quote — we export Multispan worldwide.

ModelOrdering code CategoryAlso searched as
CC 510CC 510-B1-01-WRefrigeration ControllersCC510, CC 510, CC-510
CC 520CC 520-B1-01-WRefrigeration ControllersCC520, CC 520, CC-520
CC 512CC 512-B1-01-WRefrigeration ControllersCC512, CC 512, CC-512
CC 515CC 515-B1-01-WRefrigeration ControllersCC515, CC 515, CC-515
CC 522CC 522-B1-01-WRefrigeration ControllersCC522, CC-522, CC 522
CC 525CC 525-B1-01-WRefrigeration ControllersCC525, CC 525, CC-525
CC 521CC 521-B1-01-WRefrigeration ControllersCC521, CC-521, CC 521
CC 552CC 552-B1-01-WRefrigeration ControllersCC552, CC 552, CC-552
CC 548CC 548-B1-01Refrigeration ControllersCC548, CC-548, CC 548
CC 524CC 524-B1-01Refrigeration ControllersCC524, CC-524, CC 524
TC 510TC 510-A2-01-WTemperature & Humidity ControllersTC510, TC 510, TC-510
MHC 512MHC-512-B1-01-WTemperature & Humidity ControllersMHC512, MHC-512, MHC 512
MHT-1202 / MHT-9044MHT-1202 / MHT-9044Temperature & Humidity ControllersMHT 1202, MHT-1202
VPR-22UVPR-22UProtection RelaysVPR 22U, VPR-22U
SPP-22 / V22-RYBSPP-22 / V22-RYBProtection RelaysSPP-22, SPP 22
SVR-22USVR-22UProtection RelaysSVR-22U, SVR 22U
VMR-132VMR-132Protection RelaysVMR-132, VMR 132
VMR-232VMR-232Protection RelaysVMR-232, VMR 232
VPR-35VPR-35Protection RelaysVPR-35, VPR 35
VPR-33VPR-33Protection RelaysVPR 33, VPR-33
VR-3KVR-3KProtection RelaysVR-3K, VR 3K
VR-3KNVR-3KNProtection RelaysVR-3KN, VR 3KN
OLR 50100OLR 50100Protection RelaysOLR50100, OLR-50100, OLR 50100
MPD-192MPD-192-A2-100Motor Protection RelaysMPD-192, MPD 192
DT SeriesDT-10S / 30S / 60S / 15M / 30MTimers & CountersDTSeries, DT Series, DT-Series
DI-22DI-22Timers & CountersDI-22, DI 22
DI-22UDI-22UTimers & CountersDI-22U, DI 22U
WLC 22WLC 22Water Level ControllersWLC22, WLC-22, WLC 22
WLC 35WLC 35Water Level ControllersWLC35, WLC 35, WLC-35
MS 5716RUMS 5716RU-M1Data Loggers & ScannersMS5716RU, MS 5716RU, MS-5716RU
PS24-10APS24-10ASMPS Power SuppliesPS24 10A, PS24-10A
PS24-6.5APS24-6.5ASMPS Power SuppliesPS24-6.5A, PS24 6.5A
PS24-5APS24-5ASMPS Power SuppliesPS24 5A, PS24-5A
PS48-2.5APS48-2.5ASMPS Power SuppliesPS48-2.5A, PS48 2.5A
PS12-8APS12-8ASMPS Power SuppliesPS12-8A, PS12 8A
PS15-5APS15-5ASMPS Power SuppliesPS15-5A, PS15 5A
PS24-2.5APS24-2.5ASMPS Power SuppliesPS24-2.5A, PS24 2.5A
PS12-5APS12-5ASMPS Power SuppliesPS12-5A, PS12 5A
PS24-1.5APS24-1.5ASMPS Power SuppliesPS24 1.5A, PS24-1.5A
PS24-1APS24-1ASMPS Power SuppliesPS24 1A, PS24-1A
PS12-2APS12-2ASMPS Power SuppliesPS12-2A, PS12 2A
PS24-0.83APS24-0.83ASMPS Power SuppliesPS24 0.83A, PS24-0.83A
PS12-1APS12-1ASMPS Power SuppliesPS12 1A, PS12-1A
PS10-1APS10-1ASMPS Power SuppliesPS10 1A, PS10-1A
Multispan families

How to choose the right Multispan model

Multispan has built control and protection instruments in India since 1986, and the range below is organised by function rather than by catalogue order. As the authorised Multispan distributor for the UAE and GCC, we hold fast-moving models in Dubai and can source the rest to order. The notes beneath the table explain each family, the differences between neighbouring part numbers, and the questions to settle — supply voltage, sensor type, output rating — before you fix a model.

Temperature & refrigeration controllers: match the sensor and the outputs

The Cryo CC family covers cold rooms, chillers and display cabinets. Start with the number of outputs you need: CC 510 and CC 520 are single-relay cooling controllers, while CC 512 and CC 522 add an alarm, CC 515 and CC 525 a buzzer, and CC 521 a heater output for defrost. CC 524 combines cooling, fan and defrost; CC 552 drives dual compressors. For process heating or ambient control choose TC 510, and for humidity use MHC 512 or the combined MHT-1202 / MHT-9044. Confirm the probe (NTC or PT100) and supply voltage when ordering.

Protection and motor-protection relays: size to the load, not the panel

These relays guard motors and three-phase equipment against supply faults. For a single-phase load, SVR-22U and the SPP-22 / V22-RYB single-phasing preventor watch under/over-voltage; VPR-22U covers the same on a compact base. Three-phase installations use VMR-132, VMR-232, VPR-33, VPR-35, VR-3K or VR-3KN, which add phase-sequence and phase-failure protection. For full motor cover — overload, unbalance and earth fault — specify the MPD-192, or the OLR 50100 overload relay with its built-in CT. Match the voltage range and CT rating to the actual motor.

Timers and counters: fix the range and the trigger first

Multispan timers handle sequencing, star-delta changeover and cyclic control. The DT Series is a fixed-range ON/OFF delay timer supplied to a set interval — DT-10S, DT-30S and DT-60S for seconds, DT-15M and DT-30M for minutes — so you order the range you actually need. Where one part must span several ranges, the DI-22 multi-range delay timer is adjustable, and the DI-22U adds a universal supply input that runs on a wide AC/DC voltage band. Decide the timing range, the function (ON-delay, OFF-delay or cyclic) and the control voltage before selecting.

Level and temperature monitoring: WLC controllers and the MS 5716RU scanner

For tank and sump automation, the WLC 22 water-level controller manages a single tank, while the WLC 35 handles a two-tank fill-and-transfer arrangement using conductive electrodes — pick by the number of tanks and whether you are filling or draining. Where you need to read and log many points, the MS 5716RU is a 16-channel temperature scanner and data logger that displays each channel and records the trend, which suits cold stores, ovens and QC rooms. Confirm the sensor type per channel and the electrode count before ordering.

SMPS power supplies: work back from voltage and current

The PS range are DIN-rail switch-mode supplies that power the controllers and relays above. Choose the output voltage first — 24 V is the panel default (PS24-1A up to PS24-10A), with 12 V (PS12-1A to PS12-8A), 15 V (PS15-5A) and 48 V (PS48-2.5A) options — then the current. Add roughly 30 percent headroom over your calculated load so the supply runs cool and copes with inrush; for example a 4 A load sits comfortably on the PS24-5A. The wattage in each listing (10 W to 240 W) is the quick cross-check.

Need a Multispan part or a custom panel?

Send us a model number or your requirement — our team responds fast with genuine stock, pricing and lead times across the UAE & GCC.