Warehousing sites live and die by uptime and demand charges. Our Dubai factory builds the incoming MDB, floor and mezzanine SMDBs, and FDBs that feed high-bay LED lighting, dock levellers, EV and reefer sockets, VRF and destratification fans — each panel engineered to your single-line diagram and DEWA/EtihadWE-standard practice. For cold and chilled stores we wire refrigeration and defrost control around genuine Multispan CC-series controllers and TC-510 room thermostats, with MHT/MHC humidity control for dry and produce rooms. Condenser and compressor feeders get VPR-22U/SVR-22U phase-failure protection and OLR-50100 overloads so a lost phase never spoils a chamber. APFC capacitor banks trim your kVArh penalty across big inductive loads. As an authorized Multispan distributor and multi-brand stockist (ABB, Schneider, Legrand, Eaton, Siemens), we supply the whole board from one source across all seven emirates and the GCC.
What we supply for Warehousing & Logistics
- Main, sub-main and final distribution boards (MDB/SMDB/FDB) plus lighting and small-power panels, built to IEC 61439 and DEWA/EtihadWE practice
- Automatic power-factor-correction (APFC) capacitor banks with detuned reactors to trim demand charges on refrigeration and HVAC loads
- Cold-store and HVAC control panels using Multispan CC-series refrigeration controllers, TC-510 temperature controllers and DT-series defrost timers
- Humidity control for dry and produce rooms with Multispan MHT and MHC humidity/temperature controllers
- Motor control centres (MCC) and pump/condenser feeders protected by Multispan VPR-22U, SVR-22U, SPP-22 phase relays and OLR-50100 overload relays
- ATS panels with bypass and genuine multi-brand devices (ABB, Schneider, Legrand, Eaton, Siemens, Himel) for standby power to racking, cold rooms and security
Typical electrical & control needs
- Reliable MDB/SMDB/FDB distribution for high-bay LED lighting, dock levellers, reefer and EV sockets across large warehouse floors and mezzanines
- Accurate temperature and defrost control for cold, chilled and frozen chambers to protect perishable and pharma stock
- Humidity control for dry stores, produce rooms and moisture-sensitive goods
- Power factor correction to avoid kVArh/demand penalties on big inductive HVAC, refrigeration and conveyor loads
- Phase-failure and motor protection for condensers, compressors and pumps so a single lost phase never spoils a chamber
- Standby/ATS changeover so racking, security and cold rooms ride through DEWA/EtihadWE supply interruptions